966 resultados para Biopsy, Needle


Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To compare the predictive performance and potential clinical usefulness of risk calculators of the European Randomized Study of Screening for Prostate Cancer (ERSPC RC) with and without information on prostate volume. METHODS: We studied 6 cohorts (5 European and 1 US) with a total of 15,300 men, all biopsied and with pre-biopsy TRUS measurements of prostate volume. Volume was categorized into 3 categories (25, 40, and 60 cc), to reflect use of digital rectal examination (DRE) for volume assessment. Risks of prostate cancer were calculated according to a ERSPC DRE-based RC (including PSA, DRE, prior biopsy, and prostate volume) and a PSA + DRE model (including PSA, DRE, and prior biopsy). Missing data on prostate volume were completed by single imputation. Risk predictions were evaluated with respect to calibration (graphically), discrimination (AUC curve), and clinical usefulness (net benefit, graphically assessed in decision curves). RESULTS: The AUCs of the ERSPC DRE-based RC ranged from 0.61 to 0.77 and were substantially larger than the AUCs of a model based on only PSA + DRE (ranging from 0.56 to 0.72) in each of the 6 cohorts. The ERSPC DRE-based RC provided net benefit over performing a prostate biopsy on the basis of PSA and DRE outcome in five of the six cohorts. CONCLUSIONS: Identifying men at increased risk for having a biopsy detectable prostate cancer should consider multiple factors, including an estimate of prostate volume.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A primary carcinoid tumour of the breast in a 66-year-old man was diagnosed by fine-needle aspiration cytology. The nature of the lesion was proved by histochemical and immunocytochemical studies. The importance of a conclusive diagnosis is discussed and the value of immunocytochemical analysis as an aid to cytomorphologic diagnosis is demonstrated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cisplatin and carboplatin are active in previously untreated patients with metastatic breast cancer (MBC) with mean response rates (RRs) of 50 and 32%, respectively. In pretreated patients the RR to cisplatin/carboplatin monotherapy declines markedly to <10%. Cisplatin and carboplatin have been combined with many other cytotoxics. In first-line setting high activity has been observed in combination with taxanes or vinorelbine (RRs consistently ∼60%). It appears that these newer combinations are superior to older regimens with etoposide (RRs 30 to 50%) or 5-fluorouracil (RRs 40 to 60%). Cisplatin-/carboplatin-based regimens with infusional 5-FU and epirubicin/paclitaxel/vinorelbine achieve high RRs of around 60 to 80%. However these regimens are difficult to administer in all patients because they require central venous access for continuous 5-FU infusion. In pretreated MBC the combinations of cisplatin-taxane/vinorelbine/gemcitabine or carboplatin-docetaxel/vinorelbine yield RRs of 40 to 50%, which are higher than those achieved with platinum-etoposide/5-FU. In locally advanced disease cisplatin-based regimens achieve very high RRs (>80%). This would suggest that in chemotherapy-naïve patients platinum-based therapy might have an important role to play. Additionally the synergy demonstrated between platinum compounds, taxanes and herceptin, in preclinical and clinical studies is of immense importance and the results of the two ongoing Breast Cancer International Research Group randomized phase III studies are eagerly awaited. These studies may help clarify the role of platinum compounds in the treatment of metastatic and possibly early breast cancer. © 2003 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Monocarboxylate transporters (MCTs), especially the isoforms MCT1 - MCT4, cotransport lactate and protons across the cell membranes. They are thus essential for pH regulation and homeostasis in glycolytic cells such as red blood cells (RBCs), and skeletal muscle cells during intense exercise. In 70% of the Standardbred horses the lactate transport activity (TA) in RBCs is high and transport is mediated mainly by MCTs. In the rest 30% of the Standardbreds MCT mediated transport route is not active and the TA is low. MCTs need an ancillary protein for their proper localization and functioning in the plasma membrane. The ancillary protein for MCT1 and MCT4 is a member of immunoglobulin superfamily, CD147. Here we determined the expression of MCT isoforms and CD147 in equine RBCs and gluteal muscle. We sequenced the cDNA of horse MCT1 and CD147 to achieve horse-specific antibodies and to reveal sequence variations that may affect the TA of RBCs. The amount of MCT1 and CD147 mRNA in muscle were also studied. ---- In all, 73 horses representing different breeds were used. Blood samples were drawn from the jugular vein and muscle samples were taken either from gluteal muscle using biopsy needle or during castration from expendable cremaster muscle. The TA of RBCs was studied using radiolabeled lactate and the amount of MCT isoforms and CD147 in the plasma membranes using Western blotting. The level of mRNA in muscle cells was determined using qPCR. Isoforms MCT1 and MCT2 were found in the RBCs and isoforms MCT1 and MCT4 in the muscle cells of horses. The TA of RBCs was dependent on the expression of CD147 and MCT1 in the plasma membrane. Sequence variations were found in the cDNA of both MCT1 and CD147, but they did not explain the inactivity of MCT1 mediated transport route. The single nucleotide polymorphism (SNP) Met125Val in CD147 that existed parallel with an SNP in 3´-untranslated region explained, however, attenuation in CD147 expression in Standardbreds. A single mutation Ile51Val also decreased the expression of CD147 in one Warmblood. The MCT1 and CD147 mRNA concentrations in the gluteal muscle were higher in horses with higher MCT1 and CD147 expression in RBCs and lower in horses with minor expression of CD147 and MCT1. This suggests that the bimodal distribution of TA is due to differences in transcriptional regulation that is functioning in parallel in MCT1 and CD147 gene.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: This preliminary investigation was designed to test the hypothesis that high intensity single-leg exercise can cause extensive cell DNA damage, which subsequently may affect the expression of the HO-1 gene. METHODS: Six (n=6) apparently healthy male participants (age 27 + 7 yrs, stature 174 + 12 cm, body mass 79 + 4 kg and BMI 24 + 4 kg/m2) completed 100 isolated and continuous maximal concentric contractions (minimum force = 200 N, speed of contraction = 60°/sec) of the rectus femoris muscle. Using a spring-loaded and reusable Magnum biopsy gun with a 16-gauge core disposable biopsy needle, skeletal muscle micro biopsy tissue samples were extracted at rest and following exercise. mRNA gene expression was determined via two-step quantitative real-time PCR using GAPDH as a reference gene. RESULTS: The average muscle force production was 379 + 179 N. High intensity exercise increased mitochondrial 8-OHdG concentration (P < 0.05 vs. rest) with a concomitant decrease in total antioxidant capacity (P < 0.05 vs. rest). Exercise also increased protein oxidation as quantified by protein carbonyl concentration (P < 0.05 vs. rest). HO-1 expression increased (> 2-fold change vs. rest) following exercise, and it is postulated that this change was not significant due to low subject numbers (P > 0.05). CONCLUSION: These preliminary findings tentatively suggest that maximal concentric muscle contractions can cause intracellular DNA damage with no apparent disruption to the expression of the antioxidant stress protein HO-1. Moreover, it is likely that cell oxidant stress is required to activate the signal transduction cascade related to the expression of HO-1. A large-scale study incorporating a greater subject number is warranted to fully elucidate this relationship.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Brazilian Consensus on Gastroesophageal Reflux Disease considers gastroesophageal reflux disease to be a chronic disorder related to the retrograde flow of gastroduodenal contents into the esophagus and/or adjacent organs, resulting in a variable spectrum of symptoms, with or without tissue damage. Considering the limitations of classifications currently in use, a new classification is proposed that combines three criteria - clinical, endoscopic, and pH-metric - providing a comprehensive and more complete characterization of the disease. The diagnosis begins with the presence of heartburn, acid regurgitation, and alarm manifestations (dysphagia, odynophagia, weight loss, GI bleeding, nausea and/or vomiting, and family history of cancer). Also, atypical esophageal, pulmonary, otorhinolaryngological, and oral symptoms may occur. Endoscopy is the first approach, particularly in patients over 40 yr of age and in those with alarm symptoms. Other exams are considered in particular cases, such as contrast radiological examination, scyntigraphy, manometry, and prolonged pH measurement. The clinical treatment encompasses behavioral modifications in lifestyle and pharmacological measures. Proton pump inhibitors in manufacturers' recommended doses are indicated, with doubling of the dose in more severe cases of esophagitis. The minimum time of administration is 6 wk. Patients who do not respond to medical treatment, including those with atypical manifestations, should be considered for surgical treatment. Of the complications of gastroesophageal reflux disease, Barrett's esophagus presents a potential development of adenocarcinoma; biopsies should be performed, independent of Barrett's esophagus extent or location. In this regard the designation short Barrett's is not important in terms of management and prognosis. © 2002 by Am. Coll. of Gastroenterology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the histological and systemic response to subcutaneous injection of polyethylene gel in rats. Methods: Twenty-one white male rats were divided into 3 groups (G): G1 and G2 received subcutaneous polyethylene gel injection in the dorsal midline and were sacrificed at 30 and 60 postoperative days, respectively. G3 was not exposed to the polyethylene gel and was sacrificed after 60 days. Blood levels of lactate dehydrogenase (LDH), creatine kinase (CK), and alkaline phosphatase (ALP) were evaluated. The heart, kidney, liver, adrenal gland, injection site, and adjacent tissues were histologically examined. The results were submitted to statistical analysis. Results: There was no clinical evidence of extrusion, reduction of the injected volume, or abnormalities in the adjacent tissues. Blood levels of CK and LDH were normal and similar in all groups. ALP levels were significantly lower in G2 than in G1 and G3. The systemic organs were normal on histological examination in the 3 groups evaluated. Microscopically, the polyethylene gel was surrounded by a thin pseudocapsule formation and minimal inflammatory cell response, which decreased from G1 to G2. Conclusion: The subcutaneous injection of polyethylene gel in rats elicited minimal local inflammatory response and no systemic side effects. Copyright © 2008 Informa Healthcare USA, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microbiopsy system was developed to overcome long sampling times for tissues before they are cryo-fixed by high-pressure freezing. A commercially available biopsy gun was adapted to the needs of small-organ excisions, and biopsy needles were modified to allow small samples (0.6 mm x 1.2 mm x 0.3 mm) to be taken. Specimen platelets with a central slot of the same dimensions as the biopsy are used. A self-made transfer device (in the meantime optimized by Leica-Microsystems [Vienna, Austria]) coordinates the transfer of the excised sample from the biopsy needle into the platelet slot and the subsequent loading in a specimen holder, which is then introduced into a high-pressure freezer (Leica EM PACT; Leica Microsystems, Vienna, Austria). Thirty seconds preparation time is needed from excision until high-pressure freezing. Brain, liver, kidney and muscle excisions of anesthetised rats are shown to be well frozen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Currently, in forensic medicine cross-sectional imaging gains recognition and a wide use as a non-invasive examination approach. Today, computed tomography (CT) or magnetic resonance imaging that are available for patients are unable to provide tissue information on the cellular level in a non-invasive manner and also diatom detection, DNA, bacteriological, chemical toxicological and other specific tissue analyses are impossible using radiology. We hypothesised that post-mortem minimally invasive tissue sampling using needle biopsies under CT guidance might significantly enhance the potential of virtual autopsy. The purpose of this study was to test the use of a clinically approved biopsy needle for minimally invasive post-mortem sampling of tissue specimens under CT guidance. MATERIAL AND METHODS: ACN III biopsy core needles 14 gauge x 160 mm with automatic pistol device were used on three bodies dedicated to research from the local anatomical institute. Tissue probes from the brain, heart, lung, liver, spleen, kidney and muscle tissue were obtained under CT fluoroscopy. RESULTS: CT fluoroscopy enabled accurate placement of the needle within the organs and tissues. The needles allowed for sampling of tissue probes with a mean width of 1.7 mm (range 1.2-2 mm) and the maximal length of 20 mm at all locations. The obtained tissue specimens were of sufficient size and adequate quality for histological analysis. CONCLUSION: Our results indicate that, similar to the clinical experience but in many more organs, the tissue specimens obtained using the clinically approved biopsy needle are of a sufficient size and adequate quality for a histological examination. We suggest that post-mortem biopsy using the ACN III needle under CT guidance may become a reliable method for targeted sampling of tissue probes of the body.